報警 & 異常 列表 (異常)
8600 Ceiling door open/close limit SW NG
For the door interlock type S spec, a ceiling door open
/close confirmation limit switch failed.
8601 ATC tool change arm inverter failure
ATC tool change arm inverter error signal (iAIVAL_B) turned off
.
8602 Chip pan cover interlock
[Code]
1->At the time of NC running OR loader automatic operating,
a chip pan cover is not close status.
8603 C-axis clamp / unclamp condition
[Code]
1->C-axis is not low-pressure brake condition while
C-axis cutting feed.
8604 Long tool change protection
[Code]
1->The cover open/close command is
designated while the spindle is rotating.
2->The cover open/close command is
designated when the M-tool spindle is rotating.
3->The cover open/close command is
designated when the C-axis is rotating.
4->The cover open/close command is designated
while the turret is not at the travel end of Z-axis
5->The cover open/close command is
designated when the slider was not retract position.
6->The slider advance/retract command is
designated when the cover was not open position.
7->The gripper open/close command is designated
when the slider was not advance/retract position.
8->The ATC command(M06,M288,M321,M421) is designated
when the Long tool was the turret tool.
11->The cover was not closed position during Spindle rotation.
or, Spindle rotation command was designated when the
cover was not closed position.
12->The cover was not closed position during M-spindle
rotation. or, M-spindle rotation command was designated
when the cover was not closed position.
13->The cover was not closed position during C-axis movement.
or, C-axis movement command was designated when the cover
was not closed position.
14->The cover was not closed position during axis movement.
or, axis movement command was designated when the cover
was not closed position.
15->The cover was not closed position during turret indexing.
or, turret index command was designated when the
cover was not closed position.
8605 Drive belt disconnection
The drive belt disconnected it.
[Code]
1->The Belt snap signal of EZ-axis kept OFF for the time of
MC SYSTEM PARAMETER ATC “Belt disconnection detect timer
(EZ)” setting or longer.
2->In the case of matrix magazine specification,the belt
snap signal of MGB-axis kept OFF for the time of MC
SYSTEM PARAMETER ATC “Belt disconnection detect
timer(MGB)” setting or longer.
8606 APC Door open/close limit N.G.
When the power is supplied, the open/close end limit
switches of the operator door or front door are both
ON or OFF.
[Probable Faulty Locations]
1)Malfunction of door open/close end limit switches
[Measures to Take]
1)Check and replace a faulty door open/close end limit
switch.
8607 XB cover interfered
The monitored axis entered the interference range when
XB cover for B-turret was not specified position. Or,
XB cover was not specified position when the monitored
axis was entering.
[Code]
1-> Sub-spindle or H1 turret
8608 Touch setter unit illegal
[Code]
None->Touch setter unit illegal signal kept OFF for a second
or longer ,when touch setter was not retract position.
8680 區域傳感器互鎖
門區域傳感器安裝規格中,因區域傳感器遮擋被禁止用遮擋區域
傳感器操作。
[代碼]
1->當前門未關時,裝料器運行中區域傳感器為關。
或裝料器在區域傳感器信號為關時起動運行。
2->當前門未關時,裝料器軸人工運行中區域傳感器為關。